| Monitor ID |
Test ID |
Description |
Measure |
Min* |
Max* |
Test Value* |
| 1 |
83 |
Oxygen Sensor Monitor Bank 1 - Sensor 1 |
(Raw value) |
0,3001 |
2,0001 |
1,212 |
| 1 |
84 |
Oxygen Sensor Monitor Bank 1 - Sensor 1 |
(Raw value) |
-0,03 |
0,03 |
-0,0032 |
| 2 |
1 |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
(Voltage) |
601,6 mV |
601,6 mV |
601,6 mV |
| 2 |
2 |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
(Voltage) |
601,6 mV |
601,6 mV |
601,6 mV |
| 2 |
7 |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
(Voltage) |
0,0 mV |
450,0 mV |
0,0 mV |
| 2 |
8 |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
(Voltage) |
450,0 mV |
1119,1 mV |
914,9 mV |
| 2 |
81 |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
(Voltage) |
0,0 mV |
601,6 mV |
591,8 mV |
| 2 |
82 |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
(Voltage) |
601,6 mV |
1119,1 mV |
611,3 mV |
| 2 |
83 |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
(Voltage) |
0,0 mV |
149,4 mV |
0,0 mV |
| 5 |
83 |
Oxygen Sensor Monitor Bank 2 - Sensor 1 |
(Raw value) |
0,3001 |
2,0001 |
1,1395 |
| 5 |
84 |
Oxygen Sensor Monitor Bank 2 - Sensor 1 |
(Raw value) |
-0,03 |
0,03 |
-0,0033 |
| 6 |
1 |
Oxygen Sensor Monitor Bank 2 - Sensor 2 |
(Voltage) |
601,6 mV |
601,6 mV |
601,6 mV |
| 6 |
2 |
Oxygen Sensor Monitor Bank 2 - Sensor 2 |
(Voltage) |
601,6 mV |
601,6 mV |
601,6 mV |
| 6 |
7 |
Oxygen Sensor Monitor Bank 2 - Sensor 2 |
(Voltage) |
0,0 mV |
450,0 mV |
0,0 mV |
| 6 |
8 |
Oxygen Sensor Monitor Bank 2 - Sensor 2 |
(Voltage) |
450,0 mV |
1119,1 mV |
914,9 mV |
| 6 |
81 |
Oxygen Sensor Monitor Bank 2 - Sensor 2 |
(Voltage) |
0,0 mV |
601,6 mV |
591,8 mV |
| 6 |
82 |
Oxygen Sensor Monitor Bank 2 - Sensor 2 |
(Voltage) |
601,6 mV |
1119,1 mV |
611,3 mV |
| 6 |
83 |
Oxygen Sensor Monitor Bank 2 - Sensor 2 |
(Voltage) |
0,0 mV |
149,4 mV |
0,0 mV |
| 21 |
84 |
Catalyst Monitor Bank 1 |
(Raw value) |
4096 |
65535 |
6694 |
| |
|
|
(mg O2) |
1,000 |
16,000 |
1,634 |
| 22 |
84 |
Catalyst Monitor Bank 2 |
(Raw value) |
4096 |
65535 |
6722 |
| |
|
|
(mg O2) |
1,000 |
16,000 |
1,641 |
| 41 |
85 |
Oxygen Sensor Heater Monitor Bank 1 - Sensor 1 |
(Temperature) |
699,9 °C |
1262,8 °C |
780,1 °C |
| 42 |
81 |
Oxygen Sensor Heater Monitor Bank 1 - Sensor 2 |
(Resistance) |
0 Ohm |
1344 Ohm |
108 Ohm |
| 45 |
85 |
Oxygen Sensor Heater Monitor Bank 2 - Sensor 1 |
(Temperature) |
699,9 °C |
1262,8 °C |
780,0 °C |
| 46 |
81 |
Oxygen Sensor Heater Monitor Bank 2 - Sensor 2 |
(Resistance) |
0 Ohm |
1372 Ohm |
102 Ohm |
| 71 |
80 |
Secondary Air Monitor 1 |
(Raw value) |
0,3672 |
2,0001 |
0,7032 |
| 71 |
81 |
Secondary Air Monitor 1 |
(Raw value) |
0 |
0,2031 |
0,0078 |
| 72 |
80 |
Secondary Air Monitor 2 |
(Raw value) |
0,3672 |
2,0001 |
0,5469 |
| 72 |
81 |
Secondary Air Monitor 2 |
(Raw value) |
0 |
0,2031 |
0,0078 |
| 81 |
80 |
Fuel System Monitor Bank 1 |
(Percent) |
-4,50% |
4,50% |
-0,52% |
| 81 |
82 |
Fuel System Monitor Bank 1 |
(Raw value) |
0,7001 |
1,3001 |
1,0506 |
| 82 |
80 |
Fuel System Monitor Bank 2 |
(Percent) |
-4,50% |
4,50% |
-0,47% |
| 82 |
82 |
Fuel System Monitor Bank 2 |
(Raw value) |
0,7001 |
1,3001 |
1,0242 |
| A2 |
0B |
Mis-Fire Cylinder 1 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A2 |
0C |
Mis-Fire Cylinder 1 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A3 |
0B |
Mis-Fire Cylinder 2 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A3 |
0C |
Mis-Fire Cylinder 2 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A4 |
0B |
Mis-Fire Cylinder 3 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A4 |
0C |
Mis-Fire Cylinder 3 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A5 |
0B |
Mis-Fire Cylinder 4 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A5 |
0C |
Mis-Fire Cylinder 4 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A6 |
0B |
Mis-Fire Cylinder 5 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A6 |
0C |
Mis-Fire Cylinder 5 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A7 |
0B |
Mis-Fire Cylinder 6 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A7 |
0C |
Mis-Fire Cylinder 6 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A8 |
0B |
Mis-Fire Cylinder 7 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A8 |
0C |
Mis-Fire Cylinder 7 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A9 |
0B |
Mis-Fire Cylinder 8 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |
| A9 |
0C |
Mis-Fire Cylinder 8 Data |
(Counts) |
0 counts |
65535 counts |
0 counts |