| Mode |
PID |
Module |
Comment |
| Mode 6 |
***** |
***** |
Monitoring test results for specific monitored systems |
| 6 |
00 |
E8 |
TIDs supported 01-1F |
| 6 |
01 |
E8 |
Oxygen Sensor Monitor Bank 1 - Sensor 1 |
| 6 |
02 |
E8 |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 6 |
20 |
E8 |
TIDs supported 21-3F |
| 6 |
21 |
E8 |
Catalyst Monitor Bank 1 |
| 6 |
35 |
E8 |
VVT Monitor Bank 1 |
| 6 |
39 |
E8 |
EVAP Monitor (Cap Off, 0.150") |
| 6 |
3B |
E8 |
EVAP Monitor (0.040") |
| 6 |
3C |
E8 |
EVAP Monitor (0.020") |
| 6 |
3D |
E8 |
Purge Flow Monitor |
| 6 |
40 |
E8 |
TIDs supported 41-5F |
| 6 |
41 |
E8 |
Oxygen Sensor Heater Monitor Bank 1 - Sensor 1 |
| 6 |
42 |
E8 |
Oxygen Sensor Heater Monitor Bank 1 - Sensor 2 |
| 6 |
60 |
E8 |
TIDs supported 61-7F |
| 6 |
71 |
E8 |
Secondary Air Monitor 1 |
| 6 |
80 |
E8 |
TIDs supported 81-9F |
| 6 |
A0 |
E8 |
TIDs supported A1-BF |
| 6 |
A1 |
E8 |
Misfire Cylinder 1 Data |
| 6 |
A2 |
E8 |
Misfire Cylinder 2 Data |
| 6 |
A3 |
E8 |
Misfire Cylinder 3 Data |
| Monitor ID |
Test ID |
Unit ID |
Test value |
Min value |
Max value |
Measure |
Description |
| 01 |
83 |
05 |
0.5125 |
0.2500 |
2.0001 |
(Raw value) |
Oxygen Sensor Monitor Bank 1 - Sensor 1 |
| 01 |
84 |
85 |
0.0001 |
-0.0600 |
0.0600 |
(Raw value) |
Oxygen Sensor Monitor Bank 1 - Sensor 1 |
| 02 |
05 |
10 |
50 ms |
0 ms |
900 ms |
(Time) |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
07 |
0A |
0.0 mV |
0.0 mV |
450.0 mV |
(Voltage) |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
08 |
0A |
860.0 mV |
450.0 mV |
1080.1 mV |
(Voltage) |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
81 |
0A |
621.1 mV |
0.0 mV |
630.9 mV |
(Voltage) |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
82 |
0A |
640.6 mV |
630.9 mV |
1080.1 mV |
(Voltage) |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 02 |
86 |
10 |
880 ms |
0 ms |
5000 ms |
(Time) |
Oxygen Sensor Monitor Bank 1 - Sensor 2 |
| 21 |
84 |
01 |
0 |
0 |
0 |
(Raw value) |
Catalyst Monitor Bank 1 |
| 35 |
80 |
9C |
-33.76 ° |
-51.00 ° |
-29.03 ° |
(Angle) |
VVT Monitor Bank 1 |
| 35 |
81 |
9C |
-33.76 ° |
-51.00 ° |
-29.03 ° |
(Angle) |
VVT Monitor Bank 1 |
| 39 |
80 |
81 |
0 |
0 |
0 |
(Raw value) |
EVAP Monitor (Cap Off, 0.150") |
| 3B |
81 |
81 |
0 |
0 |
0 |
(Raw value) |
EVAP Monitor (0.040") |
| 3C |
81 |
01 |
0 |
0 |
0 |
(Raw value) |
EVAP Monitor (0.020") |
| 3D |
8C |
81 |
0 |
0 |
0 |
(Raw value) |
Purge Flow Monitor |
| 3D |
88 |
81 |
0 |
0 |
0 |
(Raw value) |
Purge Flow Monitor |
| 41 |
85 |
16 |
779.8 °C |
719.9 °C |
1262.8 °C |
(Temperature) |
Oxygen Sensor Heater Monitor Bank 1 - Sensor 1 |
| 42 |
81 |
14 |
90 Ohm |
0 Ohm |
602 Ohm |
(Resistance) |
Oxygen Sensor Heater Monitor Bank 1 - Sensor 2 |
| 71 |
80 |
05 |
1.1720 |
0.3985 |
2.0001 |
(Raw value) |
Secondary Air Monitor 1 |
| 71 |
81 |
05 |
0.0547 |
0.0000 |
0.3985 |
(Raw value) |
Secondary Air Monitor 1 |
| A2 |
0B |
24 |
0 counts |
0 counts |
0 counts |
(Counts) |
Misfire Cylinder 1 Data |
| A2 |
0C |
24 |
3 counts |
0 counts |
65535 counts |
(Counts) |
Misfire Cylinder 1 Data |
| A3 |
0B |
24 |
0 counts |
0 counts |
0 counts |
(Counts) |
Misfire Cylinder 2 Data |
| A3 |
0C |
24 |
0 counts |
0 counts |
65535 counts |
(Counts) |
Misfire Cylinder 2 Data |
| A4 |
0B |
24 |
0 counts |
0 counts |
0 counts |
(Counts) |
Misfire Cylinder 3 Data |
| A4 |
0C |
24 |
3 counts |
0 counts |
65535 counts |
(Counts) |
Misfire Cylinder 3 Data |